top of page
空景.jpg

OBC & DCDC
INTEGRATED UNIT

2 In 1 OBC+DCDC

Electric vehicles are equipped with batteries with lighter weight and higher power density, which can not only increase driving range, but also potentially be used to support independent loads.

The on-board charging system is installed on an electric vehicle to adjust the AC or DC input power to a calibrated voltage/electricity.

Product: 11kw OBC+3kw DCDC

液冷二合一图 11kwOBC 3kwDCDC.jpg
               2 In 1 
     Liquid Cooled 

On Board Charger 

​Nominal Output power:          11kW

Input Voltage Range :              304-456Vac(3 phase 4 wire)

Power Factor:                              ≥0.99(220Vac, full load)

Input Current:                             32A Max

Output Voltage Range:            250-450Vdc/500-750Vdc                    

Max. Output Current:                32A/20A

Efficiency:                                     ≥94%

Voltage Accuracy:                       ±1%

Current accuracy:                        ±1%

DC/DC Converter

​Nominal Power:                         3kW

Input Voltage Range :              250-450Vdc/500-750Vdc

output Voltage Range:            9-16V

Nominal Voltage:                      14V

Nominal Output Current :      215A               

Peak Power:                               3.6kW

Voltage ripple:                           300mV Max

Efficiency:                                    ≥94%

Other Electrical Feature

Operation Temperature:      -40℃~85℃, Coolant inlet temperature

Low Voltage Wake-up:          12Vdc&200mAmax(WAKE_UP signal), Wake up BMS/VCU

Voltage Wake-up:                   CAN/AC/HVDC/CC/CP/EN, support reserve charging 

CAN Communication:            CAN-BUS

Static Current:                          1mA, sleep mode/consume battery current at stop status

Protection:                                 Input OVP, UVP, output OVP, UVP, OTP, OCP, output short                                                            circuit protection, communication fault protection.

Advantages:

Sinovation EV 2 In 1 Unit including 6.6-11kw OBC and 2-3kw DCDC, have fan cooled and liquid cooled type and supporting on-line upgrade and fault diagnosis, full digital software design ,redundant protection function design.